Product Range of Heating Cables

Mineral Insulated Heating Cables range is divided into 3 groups, depending on metallic type of the outer sheath

The metallic core can be chosen according to the desired output power (depending from conductor specific resistance):

  • Copper (from 4 to Ω88 /km)
  • Kumanal (from 100 to 2700 Ω/km)
  • Nickel Chrome (from 160 to 10000 Ω/km)

COPPER CABLES

Bare Copper Sheathed
Covered Coppper Sheathed
 
Cable Type
 
 
Resistance
 
 
Outer Diameter
 
 
Conductor Diameter
 
 
Cable Type
 
 
Outer Diameter
 
 
code
 
 
Ω/km
 
 
mm
 
 
mm
 
 
code
 
 
mm
 
KC 2700  
2700
 
 
2.7
 
 
0.44
 
 
KC 2700 / HDPE
 
 
4.3
 
KC 2000  
2000
 
 
2.8
 
 
0.51
 
 
KC 2000 / HDPE
 
 
4.4
 
KC 1600  
1600
 
 
3.5
 
 
0.57
 
 
KC 1600 / HDPE
 
 
5.1
 
KC 1250  
1250
 
 
2.8
 
 
0.65
 
 
KC 1250 / HDPE
 
 
4.4
 
KC 800  
800
 
 
3.5
 
 
0.81
 
 
KC 800 / HDPE
 
 
5.1
 
KC 630  
630
 
 
4.0
 
 
0.91
 
 
KC 630 / HDPE
 
 
5.6
 
KC 450  
450
 
 
4.0
 
 
1.08
 
 
KC 450 / HDPE
 
 
5.6
 
KC 315  
315
 
 
4.3
 
 
1.29
 
 
KC 315 / HDPE
 
 
5.9
 
KC 220  
220
 
 
4.5
 
 
1.54
 
 
KC 220 / HDPE
 
 
6.1
 
KC 140  
140
 
 
4.9
 
 
1.93
 
 
KC 140 / HDPE
 
 
6.5
 
KC 100  
100
 
 
5.2
 
 
2.28
 
 
KC 100 / HDPE
 
 
6.8
 
CC 88  
88
 
 
2.7
 
 
0.50
 
 
CC 88 / HDPE
 
 
4.3
 
CC 63  
63
 
 
3.2
 
 
0.59
 
 
CC 63 / HDPE
 
 
4.8
 
CC 40  
40
 
 
3.4
 
 
0.74
 
 
CC 40 / HDPE
 
 
5.0
 
CC 25  
25
 
 
3.7
 
 
0.94
 
 
CC 25 / HDPE
 
 
5.3
 
CC 17  
17
 
 
4.6
 
 
1.13
 
 
CC 17 / HDPE
 
 
6.2
 
CC 11  
11
 
 
4.9
 
 
1.38
 
 
CC 11 / HDPE
 
 
6.5
 
CC 7  
7
 
 
5.3
 
 
1.78
 
 
CC 7 / HDPE
 
 
6.9
 
CC 4  
4
 
 
5.9
 
 
2.26
 
 
CC 4 / HDPE
 
 
7.5
 

CC: Copper core, Copper sheath
KC: Kumanal core, Copper sheath
HDPE = High Density Polyethylene

CUPRO-NICKEL CABLES

 
Cable Type
code
 
 
Resistance
Ω/km
 
 
Outer Diameter
mm
 
 
Conductor Diameter
mm
 
KN 1600  
1600
 
 
3.2
 
 
0.57
 
KN 1000  
1000
 
 
3.4
 
 
0.72
 
KN 630  
630
 
 
3.7
 
 
0.91
 
KN 400  
400
 
 
4.0
 
 
1.14
 
KN 250  
250
 
 
4.4
 
 
1.45
 
KN 160  
160
 
 
4.9
 
 
1.81
 
CN 63  
63
 
 
3.2
 
 
0.59
 
CN 40  
40
 
 
3.4
 
 
0.74
 
CN 25  
25
 
 
3.7
 
 
0.94
 
CN 17  
17
 
 
4.6
 
 
1.13
 
CN 11  
11
 
 
4.9
 
 
1.38
 
CN 7  
7
 
 
5.3
 
 
1.78
 
CN 4  
4
 
 
5.9
 
 
2.26
 

KN: Kumanal core, Cupro Nickel sheath
CN: Copper core, Cupro Nickel sheath

STAINLESS STEEL AND INCONEL SHEATHED

Stainless Steel
Inconel
 
Cable Type
 
 
Resistance
 
 
Outer Diameter
 
 
Conductor Diameter
 
 
Cable Type
 
 
code
 
 
Ω/km
 
 
mm
 
 
mm
 
 
code
 
TI 10K  
10000
 
 
3.2
 
 
0.38
 
 
TINC 10K
 
TI 6300  
6300
 
 
3.2
 
 
0.48
 
 
TINC 6300
 
TI 4000  
4000
 
 
3.2
 
 
0.61
 
 
TINC 4000
 
TI 2500  
2500
 
 
3.4
 
 
0.77
 
 
TINC 2500
 
TI 1600  
1600
 
 
3.6
 
 
0.96
 
 
TINC 1600
 
TI 1000  
1000
 
 
3.9
 
 
1.21
 
 
TINC 1000
 
TI 630  
630
 
 
4.3
 
 
1.49
 
 
TINC 630
 
TI 400  
400
 
 
4.7
 
 
1.87
 
 
TINC 400
 
TI 250  
250
 
 
5.3
 
 
2.37
 
 
TINC 250
 
TI 160  
160
 
 
6.5
 
 
3.03
 
 
TINC 160
 

TI: Nickel Chrome core, Stainless Steel sheath
TINC: Nickel Chrome core, Inconel sheath

CONTACT