End caps are in accordance with EEMUA – 234, Section 1 and seamless.

Dimensions
Dimensions are based on EEMUA - 234, Section 1, Figure 1.1, Tables 1.1-1.2 and 1.8. The additional wall compensatory thicknesses over and above the minimum pipe wall thicknesses are included. Caps with other dimensions are available on request.

Tolerances
See Appendix C

Weld Preparation
For wall thickness less than 3 mm, the caps are supplied with plain weld ends. Larger thicknesses are supplied with the weld bevel of 37 ½°±2 ½°.

 

16 Bar

20 Bar

Approx. Weight

Specified

t min

H

t min

H

16 bar

20bar

Size OD

mm

mm

mm

mm

kg

kg

44.5

Use 20 Bar

2.25

19.6

Use 20 bar

0.08

57

2.25

22

0.11

76.1

2.25

25.7

0.18

88.9

2.25

28.2

0.24

108

2.70

31.7

0.40

159

2.63

41

3.12

44

0.8

0.97

219.1

3.54

55

4.29

60

2

2.40

267

4.29

69

5.23

69

3.4

4.10

323.9

5.24

80

6.34

85

5.9

7.70

368

5.90

93

7.21

103

9.1

11.90

419

6.73

102

8.21

112

12.4

16.90

457.2

7.33

119

8.97

119

17.6

20.90

508

8.15

129

9.96

139

22.7

30.80

610

9.81

148

11.96

163

39.2

51.60

711

11.50

176

13.97

191

61.8

81.40

813

13.17

200

15.97

210

90.5

117.40

914

14.81

221

17.96

231

132.2

166.20